Im ready to send my back for a replacement. The best pool timers allow you to keep your swimming pool spotless without needing to run your pump around the clock. Two days ago after my pool pump shut off automatically I decided to turn it back on because the pool was still dirty. I have replaced the trippers, but the problem persists. It is twisted clockwise or counterclockwise until the correct current time lines up with the "Time" marker, which points directly downward at all times while the clock dial constantly turns. We are on our third timer. I have a PF1112T. Hey there! The time does not advance after resetting. $829,900. You can check these easily by removing them and inspecting them for damage. Faulty Pump or Wiring from the Timer to the Pump. Ive reset the time 5 times and just realized that its going counter clockwise. Intermatic time clock motors can be replaced, but unless the time clock is brand new, its best to replace the entire Intermatic mechanism. Thanks. You may notice that the time pointer is loose or is moving around too much.If you find your pointer is loose, simply tighten the screw that holds the timer in place so that it doesnt wiggle around. However, intermittently after the ON tripper switches pump on the pump will stop. Check that dial is not warped. Home / Pool Repairs / Equipment Repairs / Intermatic Pool Timer Troubleshooting. Commonly, many pool owners will think there pool timer is broken and not working when all they had to to is turn the circuit breaker to the on position. If you run rope/twine through the Air Pillow grommets, you can tie them to each other and run the rope/string to opposite sides of the pool, tying it off, so they will stay in the middle. More. There is also a light switch for the lighting in the pool in the control panel and when i turn on the switch the light in the pool turns on. Does it need lubricant or something? Basically 12 real life hours equals about 14 on the timer. Pool and Spa Expert: Mike_G2010 With the switch up it is in Auto mode. I replaced T104 timer it runs and shuts off with no issue but once off the timer does not move or turn back on. Thank you, I dont know about the box, was just told the mechanical timer a T104 is needed. Thanks for your help! Or may be bent and not come together. You can always call us at 815-675-7000 M-F 8am-4:30pm CST and . Sometimes its way quick just to replace it rather than spend hours troubleshooting. Spray WD-40 or any kind of lubricant onto the manual lever to loosen it. There's an issue with the wiring between the circuit breaker and the timer. Back when I was a young technician I was taught to always look for the easy things and use all my senses. I looked through the visual motor check and the gear still moving fine. Since it came out of the box today, it probably is not trash in the gears.It seems the plastic gears and/or the coil in the clock mechanism are not strong enough to engage the on/off points or not for long. Intermatic time clocks are the workhorse of your pool equipment collection, and oftentimes outlive the equipment they control. You may need to adjust the meshing of the timer motor gear so it runs the clock. And does the switch look worn, where the tripper engages? Save my name, email, and website in this browser for the next time I comment. 3. To adjust the time you will first want to look for the time bar that is mounted in the middle of the timer wheel. VIDEO TOUR. Hi, new timer out of the box, 200V. Southern Queensland Country Tourism CEO Peter Homan says water park could convert 'day trippers' to overnight visitors to Toowoomba The region's peak tourism body has claimed a widely requested water park could increase Toowoomba's appeal to a new era of visitors, as council says a park was not a priority in the coming decade. Clean the gears with a toothbrush if you see debris or gunk in them. A wire inside the motor may be touching another wire, or the metal sides of the motor. do i need to do something different? Can the pool timer be placed inside the garage to protect it from the harsh weather. You can always call us at 815-675-7000 M-F 8am-4:30pm CST and speak with a live technician. If the power has gone out, your just opening your swimming pool for the season or some third reason, you may need to adjust the time on your Intermatic swimming pool timer. Test the voltage coming in, it may be incorrect, or out of range (more than 10% above 110v or 220V). What was the fix?? "url": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide",
The motor is running and I turn off using breaker in the electical box, I put a new timer in and does the same thing. "datePublished": "1/10/2020",
If power is reaching the clock, but the motor gears are not turning, that usually means either something is jammed in the gears, or the timer motor has burned out. I have the pool timer with the red teeth that you pop up or down depending on when you want the pool to run. My timer doesnt seem to be working or my pump in either speed. LIMITED TO A ONE-TIME RUN OF 666 UNITS. Common timer problems include the clock not turning, not switching the pump on/off, loose timer pointer and a stopped clock. Also I have rotated the dial several times to trip on and off hoping that it lubricates the problem lever and dusts off the coil well. AJH Trade Group is a participant in the Amazon Services LLC Associates Program. "
Report B BadOleRoss 0 LifeTime Supporter Apr 30, 2011 393 Lynchburg VA Aug 21, 2012 #8 Assuming the wiring is all correct. Also check that the motor number is compatible with your clock model. Karl, good question. Posted by 4 years ago. make sure it hasnt tripped and is switched on. Replace a new T104. If its not, then the timer will not turn on/off at the correct times. I am having the same problem. My original timer worked for 5 years then the clock stopped and I heard no sound. charging for timer($150.00) and filter cartridge replacement ($90.00) and a gasket($25.00)called bc of a hose leak, assume that is the gasket but then told that the other 2 parts are needed. I believe its the manual on/off switch that is the problem. We like that this pool timer because it is made from heavy-duty material and two grounded outlet makes it safe and durable. How can I fix this? You should be able to see the gears moving. Proceed to step 4 to check the timer itself. If all looks tight and no foreign objects or insects are found to be in there, and the switch mechanism does not look worn (the silver part next to the tab you manually flip to turn on/off), then its probably a failing timer motor. Does this give you a better idea of the problem? Still no luck. You dont have two OFF trippers, right? Shannon, compare the wiring to the diagram for Line and Load (line is power coming in, Load is power out to your pump). If not, that sounds like a weak/bad motor. Jul 20, 2021. "@type": "ImageObject",
Problems with Intermatic timers are caused by defective trippers, incorrect wiring, tripped circuit breakers, a faulty time clock motor and incorrectly set power terminals. Ive seen it happen from lightning strikes, or insect infestation. Terminal A (farthest to the left side) is not connected to anything. Are the gears engaged, in the center, behind the dial? AJH Trade Group Australia Pool Equipment | Pool Lifestyle | Pool Heating | Pool Maintenance | Pool Problems, what to do when the pump circuit breaker continually trips. Check that the TEST button has not popped out. Yes, seen that before! Hi Derrick, first try to reposition the timer tripper, making sure it is all the way on the dial. I currently manually turn it on and off. Hi Casey, perhaps the cord or wires are broken? Any suggestions? The timer motor cover (the oval silver box with the printing) can be pried off with a sharp screwdriver. http://waterheatertimer.org/Tork-timers-and-manuals.html I look through the window of the panel and see the gears running well. After this has been removed, you can turn the breaker back on and measure for the voltage on the timer input. It I set the timer again it will jeep time until it gets to the next dog ear. I have a intermatic T101 and the clock doesnt move I replaced the old one due to burned out motor . "logo": {
The 240V or the T104 models have 5 brass screws (terminals) underneath the plastic insulator cover. I guess if they look the same as before maybe the dial is warped? Or if power is interrupted to the pool pad, for some reason, maybe breakers flipped off for some electrical work? Also known as an RCD (residual current device) in Australia and the UK. The other gears move very slowly, and appear to not move at all, except for one I believe? Turn the power off at the breaker box and carefully remove the wires to the clock. Does the motor gradually start running slowly? They are little ants that just came. If dial is rotating correctly, but water heater never turns on-off, then trippers might be bad. I have Model T40004RTe. Push the tab on the top, and let the mechanism fall forward. The trippers will "trip" the analog clock to turn on and off automatically at the set times. We may earn a small commission. Depends maybe on what it is getting stuck on, or what is catching the tripper, and are the motor gears still turning when it gets stuck? Put a meter on the wires or trace them back to find out their voltage and source. The works fine and keeps time while it is on but the second it turns the filter off, it stops keeping time and the cogs stop moving. It was always fine before. Is it possible to do this by loosening the timer screw a bit? Simply screw it back into place until its snug. I flicked the switch between on and off and it will not shut off. It has 4 screws below the dial labeled from left to right: LINE 1, LINE 2, LOAD 1, LOAD 2. Hi. Then number(time of day) that you line up with the time marker will be the time that you are setting your timer to. However, the timer will stop around 10pm everyday and will not continue moving forward again. Hi Ryan, that sounds like a bad motor or a broken gear, you can replace just the motor, or the entire clock mechanism. Terry, unusual but check all connections, making sure that bare wire is tightly contacting the terminal screw plates. 120Volt Tork 1101 timers can be fixed with repair parts. Sometimes bugs get in there and jam the gears, sometimes debris is the issue and other times the gears get old and may lose a tooth. Turn the manual on/off switch. HI Ben, yes just remove the OFF tripper, and the clock will always be ON. It should be 110V or 220V AC. Turn in either direction and align the exact time-of-day on .
Shira And Diego,
Articles P